Safety SolutionsGroup

Water-based suppression

Automatic fire suppression systems: sprinklers, pump stations, hydrants

For residential complexes, shopping centres, warehouses, car parks and industrial sites we design, install and maintain water-based automatic suppression: sprinkler networks (wet, dry, deluge, pre-action), water mist, fire pump stations, internal and external hydrants. Designs are approved with the fire authority and the equipment is certified.

  • 4 sprinkler types + water mist
  • Pump stations and hydrants
  • Fire authority approval
  • Water mist system at the Olympic Stadium
Pump station pipework and valves
founded
2017
completed projects
500+
clients
200+

Types of sprinkler systems

A sprinkler head opens only when heat reaches it, so water goes only where the fire is. The system type depends on room temperature, fire load and how critical a false discharge would be.

  • Wet system

    Pipes are always full of water; it flows as soon as a head opens. The simplest and most common type: offices, shopping centres, residential buildings, heated warehouses.

  • Dry system

    Pipes hold compressed air or nitrogen; water enters after the valve. For places at risk of freezing: unheated warehouses, open car parks, cold stores.

  • Deluge system

    Heads are open; the valve is released by the fire alarm and the whole zone is flooded. For fast-spreading fire risks: transformers, fuel, chemical stores.

  • Pre-action system

    Water is released only when a detector and a head both trigger, minimising accidental discharge. Server rooms, archives, museums.

Water mist systems

High pressure turns water into very fine droplets: heat is removed quickly with little water and oxygen is limited. For large areas with many people and where water damage must stay low. At Baku Olympic Stadium we have maintained the water mist, Inergen and FM-200 systems since 2022.

Fire pump stations and hydrants

The pump station gives the sprinkler and hydrant network the required pressure and flow: main electric pump, standby (diesel or second electric) pump, jockey pump, control cabinet, valves. Internal hydrants (landing valves) go on each floor, external hydrants across the site. We work with Turkuaz Pompa, Kızılkaya, Armaş, Shield and Duyar equipment.

  • Pump station calculation and installation
  • Pipework, gate valves, check valves
  • Internal landing valves and cabinets
  • External hydrants and connection to the water tank

Which sites it suits

Residential complexes and high-rise buildings, shopping centres and hotels, warehouses and logistics centres, underground and multi-storey car parks, industrial sites, stadiums and public buildings. For construction companies and fit-out contractors we work from the design stage.

How the work goes

Site visit or review of the design documents, choice of system type by fire load, hydraulic calculation, fire authority approval, equipment supply, installation and pressure test, commissioning certificate. Then periodic checks of pumps, valves and heads under an annual contract.

Projects

Projects where we installed this system

Brands we use for this system

How it goes

Five steps from enquiry to maintenance

  1. 1

    Site survey

    Free. We visit the site and define the requirements, cable routes and existing systems on the spot.

  2. 2

    Design and quote

    Layout, equipment list and quotation within 1–3 working days; fire authority approval where the project needs it.

  3. 3

    Installation

    By our own technical team, around the site’s working schedule.

  4. 4

    Testing and handover

    We test the system, train the users and hand over the acceptance certificate and documents.

  5. 5

    Maintenance

    6–12 months’ installation warranty; annual contract with periodic checks and fault call-outs.

Frequently asked questions

Questions about this service

A wet system for a heated warehouse, a dry system for an unheated or cold one. High racks and combustible goods need special heads and densities. The exact answer depends on fire load and rack height.

Contact

Free calculation for your project

Send the site plan or book a visit: we prepare the system type, the pump station and the quote.

Baku office

Baku, Narimanov district, Ağa Nemətulla str. 247

+994 50 453 33 45 · info@safetysolutions.az

Mon–Fri 09:00–18:00 · emergency call-outs outside office hours

Georgia

Gzatkecili 15km, Rustavi

+995 593 10 33 36

info@safetysolutions.ge

Send a request

Your details are used only to answer your request.

CallWhatsApp